品牌 | 旭明 | 執行質量標準 | 國標 |
---|---|---|---|
產地 | 國產 | 加工定制 | 是 |
XM大型地網接地阻抗測試儀注意事項:
1、為使測試順利進行,測試前請先用萬用表檢查測試導線與地樁的接觸點是否完好,并測量已放好的線是否有斷路現象。
2、四極法測量時儀器會自動消除接線誤差。
3、當光標在電流上時候,按一(yi)下“確(que)認”鍵,在屏幕左下角會(hui)出現或(huo)消(xiao)失打印機(ji)小(xiao)符號(hao),代表選擇(ze)或(huo)取(qu)消(xiao)自動打印功能
XM大型地網接地阻抗測試儀產品別稱:
大地(di)(di)(di)網接(jie)(jie)(jie)地(di)(di)(di)電(dian)阻測(ce)(ce)試(shi)儀(yi),變(bian)頻(pin)大電(dian)流(liu)接(jie)(jie)(jie)地(di)(di)(di)阻抗測(ce)(ce)試(shi)儀(yi),大型接(jie)(jie)(jie)地(di)(di)(di)網接(jie)(jie)(jie)地(di)(di)(di)阻抗測(ce)(ce)試(shi)系統(tong)(tong)、接(jie)(jie)(jie)地(di)(di)(di)裝置特性參數測(ce)(ce)試(shi)系統(tong)(tong)、大地(di)(di)(di)網接(jie)(jie)(jie)地(di)(di)(di)阻抗測(ce)(ce)試(shi)儀(yi),接(jie)(jie)(jie)地(di)(di)(di)阻抗測(ce)(ce)試(shi)儀(yi),變(bian)頻(pin)抗干擾接(jie)(jie)(jie)地(di)(di)(di)阻抗測(ce)(ce)試(shi)儀(yi)、變(bian)電(dian)站接(jie)(jie)(jie)地(di)(di)(di)網接(jie)(jie)(jie)地(di)(di)(di)特性參數測(ce)(ce)試(shi)儀(yi)、變(bian)頻(pin)大電(dian)流(liu)多功能(neng)接(jie)(jie)(jie)地(di)(di)(di)阻抗測(ce)(ce)試(shi)儀(yi)等
操作步驟:
1.連接儀器測試線(xian):按照下圖(tu)所示連接測試線(xian)(粗線(xian)接電(dian)流輸出端口,細線(xian)接電(dian)阻(zu)檢測端口)。
2.接(jie)通儀器電源,按下電源開關(guan),預(yu)熱5分鐘。
3.按要求選擇(ze)測試量程開關,一般選擇(ze)600mΩ檔。
4.將電流旋鈕逆(ni)時(shi)針旋至零(ling)位,然后(hou)將兩組測試夾相(xiang)互(hu)短(duan)路。
5.根據需要(yao)選擇手動(dong)測(ce)試(shi)或定時(shi)測(ce)試(shi)(手動(dong)測(ce)試(shi)時(shi)定時(shi)開關為(wei)“關”,自動(dong)定時(shi)測(ce)試(shi)時(shi)定時(shi)開關為(wei)“開”)。
6.檢查條件設定無誤后,按動(dong)“啟動(dong)”按鈕,測試燈(deng)亮,調節“電流調節”旋鈕至(zhi)所選擇的電流值(一(yi)般為12A)。
7.將(jiang)“預(yu)(yu)置(zhi)(zhi)/測試(shi)”開關置(zhi)(zhi)于“預(yu)(yu)置(zhi)(zhi)”狀態,調節“報(bao)警(jing)電阻調節”電位器,預(yu)(yu)置(zhi)(zhi)報(bao)警(jing)電阻值為(wei)500mΩ。(需(xu)要有(you)電流輸(shu)出的情況下(xia),才可預(yu)(yu)置(zhi)(zhi)報(bao)警(jing)電阻值)。
主要用途:
是主要用(yong)于精確(que)測量大型接(jie)(jie)地網接(jie)(jie)地阻抗、接(jie)(jie)地電(dian)(dian)(dian)阻、接(jie)(jie)地電(dian)(dian)(dian)抗、場(chang)區(qu)地表電(dian)(dian)(dian)位梯度、接(jie)(jie)觸電(dian)(dian)(dian)位差、接(jie)(jie)觸電(dian)(dian)(dian)壓、跨(kua)步(bu)電(dian)(dian)(dian)位差、跨(kua)步(bu)電(dian)(dian)(dian)壓、轉移電(dian)(dian)(dian)位、接(jie)(jie)地引下線導通電(dian)(dian)(dian)阻、土壤(rang)電(dian)(dian)(dian)阻率(lv)等接(jie)(jie)地特性參(can)數(shu)的(de)軟硬件系統(tong)。采用(yong)逐(zhu)點變頻(pin),抗干擾(rao)*,能在強(qiang)干擾(rao)環境(jing)下準確(que)測得工頻(pin)50Hz下的(de)數(shu)據(ju)。系統(tong)輸出功(gong)率(lv)大(2-20KW),電(dian)(dian)(dian)壓高(gao)(0-1000V),輸出電(dian)(dian)(dian)流大(0-50A),不會引起測試時(shi)接(jie)(jie)地裝置的(de)電(dian)(dian)(dian)位過(guo)高(gao),同時(shi)它還具有*的(de)抗干擾(rao)能力(li),故(gu)可以在不停電(dian)(dian)(dian)的(de)情況下進(jin)行測量